Oxima® 3 Light weight  vital signs patient Monitor

It can be applied in the hospital's operation room ICU clinic section office
Out-patient department sickroom and emergency treatment.

Product Features

    Efficient performance patient monitor
    Easy to use
    Four parameters: NIBP. SpO2. Pulse Rate. TEMP
    Suitable for adult pediatric and neonatal
    Battery capacity indicator and prompt when battery low
    Large screen : SpO2 PR are shown on LED screen Pleth waveform is displayed on 2.8" color screen in real time
    24 hours or AC power and Built-in rechargeable Li-ion battery up to 6 hour running time
    Storage/Review trend data up to 3888 groups data save time interval settable
    Automatic shutdown for power saving shutdown time interval settable
    Audio and visual alarm when parameters exceeded and sensor-off
     
    Options
    Thermal Printer

Product Specifications

    Oxima® 3 Vital signs monitor three parameters: NIBP,SpO2 and TEMP
     
    NIBP: 
    Measurement method: Oscillometric 
    Range: Adult: 30mmHg~255mmHg Pediatric: 30mmHg~160mmHg 
    Measurement unite: MmHg/kPa selectable 
    Measurement mode: Manual Auto STAT 
    Measurement Type: SYS DIA MAP 
    Measurement interval in AUTO mode: 1 2 3 5 10 15 20 30 45 60Min 
    Measuring period in STAT mode: 5 Min 
    Resolution: 1mmHg 
    Over-pressure protection: Adult: 300mmHg Pediatric: 220mmHg 
     
    SpO2: 
    Range: 0 -100% 
    Resolution: 1 % 
    Accuracy: 2% (90~99%) 3% (70~89%) unspecified (< 70%) 
     
    PR: 
    Range: 30bpm~250bpm 
    Resolution: 1bpm 
    Accuracy: 2bpm 

    TEMPERATURE 
    Channel                                   2
    Measuring and Alarm Range   0 ~ 50 °C
    Resolution                                0.1°C
    Accuracy                                 ±0.1°C
    Actualization interval               about 1 Sec.
    Average Time Constant          < 10 Sec.

    IBP (optional)
    Channel         2
    Label              ART, PA, CVP, RAP, LAP, ICP, P1, P2
    Measuring and alarm range 
                         ART                0~300mmHg
                         PA                  -6~120mmHg
                         CVP/RAP/LAP/ICP   -10~40mmHg
                         P1~P2              -10~300mmHg
    Press Sensor
                   Sensitivity              5 uV/V/mmHg
                   Impedance             300-3000Ω
    Resolution                           1mmHg
    Accuracy                              ±2% or 1mmHg which great
    Actualization Interval            about 1 Sec
     
    Power Requirements: 
    AC power adaptor 
    Input: AC 100~240V 50/60Hz 0.7A 
    Output: 5V 2.5A 
    Internal battery 
    Type: 2.8A build-in Li-ion rechargeable battery 
    Operating Time: 6 hours of stand-by time with a full battery. 
    Recharge time: 8 hours 
     
    Oevice dimension: 210mm × 188mm × 107mm 
    Net Weight: 1000g
     
$(document).ready(function(e) { $('.updown h2').click(function () { $(this).toggleClass('ttt').next("ul.tttli").slideToggle("fast"); }); });

Related Products

Promoted Products

Shandong Hillinton Medical Equipment Co.,Ltd is part of Magina Group. Product(s) described may not be licensed or available for sale in all countries. Sonotech, Sonovet, iSonic, FOs2pro, Dolphi, Defi, HeartRec,miniScan,Cardios,SpirOx,iBreath, Hillinton and all corresponding design marks are trademarks of Hillinton. The symbol indicates the trademark is registered. Patent and Trademark Office and certain other countries. All other names and marks mentioned are the trade names, trademarks or service marks of their respective owners. Please see the Instructions for Use for a complete listing of the indications, contraindications, warnings and precautions.